102.5mm Xtratherm Thermal Line XT/TL (MF)

102.5mm Xtratherm Thermal Line XT/TL (MF)

  • Documentation
  • 0 reviews
    £74.21 EX VAT £89.05 INC VAT

    Additional Info

    Brand:
    Xtratherm
    Product Code:
    C-199
    • Application:
      Plasterboard for internal walls, sloped roofs and ceilings.
    • Type:
      Insulation for drylining wall (mechanically fixed)
    • Product Size:
      1200mm x 2400mm
    • Thickness:
      102.5mm
    • Pack Coverage:
      2.88m2
    • Estimated Delivery:
      2-3 Working days

    Product Description

    Xtratherm Thermal Line XT/TL (MF)

    Thin-R Thermal Liner Mechanically Fixed XT/TL-MF is a composite insulated panel of Xtratherm PIR insulation core with a composite foil facing bonded to 12.5mm tapered edge plasterboard for internal walls, sloped roofs and ceilings. XT/TL-MF is only suitable for mechanically fixed applications.

    The composite foil facing on both sides of XT/TL-MF incorporates an integral vapour control layer, which helps to reduce the risk of condensation. XT/TL-MF is designed to provide high levels of thermal insulation and drylining in one operation, providing the solution of choice in newbuild and renovation.

    Key Facts :
    Insulation & Drylining in one Application
    Provides Continuous Vapour Control Layer
    Reduced Insulation Thickness
    Suitable for a Variety of Wall Types
    Cost Effective Solution in Refurbishment and New Build

    Thickness: 102.5mm (90mm PIR Insulation+12.5mm Plasterboard)
    Length: 1200mm
    Width: 2400mm
    Board coverage: 2.88m2
    Weight/m2: 11.21kg
    Weight: 32.28kg
    Density: 109.04kg/m3
    Thermal conductivity: 0.022 WmK
    Thermal resistance: 4.09m2K/W
    Fire resistance: Class 1
    Edge profile: Plasterboard – Tapered ; PIR – Square Edge
    Minimum compressive strength at 10% compression (kPa): 140

     

             

    1) Integral vapour control layer The composite foil facing on XT/TL-MF provides a gas and vapour tight barrier, reducing the condensation risk. A continuous vapour control layer is created when the XT/TL-MF joints are sealed and taped in accordance with drylining good practice.
    2) Fire Stops
    An important factor when drylining a wall is to provide fire stops along the top and bottom of each board and around all openings (doors, windows, etc). These are provided by the battens and prevent fire penetrating behind the insulation layer. This also helps to prevent thermal looping, leading to an overall improved U-Value for the wall element.
    3)Service Void The void created between the timber battens can be used for accommodating services.


    General:
    Xtratherm XT/TL Thermal Liner is for use as an insulating dry lining system for solid or cavity masonry walls and
    horizontal or sloped timber roofs of existing and new dwellings, or buildings of a similar nature. It should be installed in
    accordance with the Certificate holder’s instructions


    Installation Guidelines:
    1)Ensure the wall is dry, clean and free of protrusions. Any existing wallpaper should be removed.
    2)Fix metal frame system/timber battens to the wall in accordance with the manufacturer’s instructions. Sections should be placed around all wall edges and around openings and services.
    3)Fix the metal frame system/vertical timber battens at a maximum of 600mm centres (incorporating a vertical DPC behind timber battens). Ensure framing system/battens are wide enough to offer 20mm support to all four edges of the plasterboard. Pack battens if necessary to level the wall. Extra noggins may be required when the XT/TL-MF is unsupported by the battens.
    4)Lift the XT/TL-MF into position using wedges on the floor. Insulation should be cut back to accommodate an adjoining panel at external corners. Joints should be tightly butted.
    5)Fix XT/TL-MF to the frame at 300mm centres using appropriate fixings eg. drywall screws, at least 12mm in from the board edge. The fixings should penetrate at least 25mm into the timber batten. Fixings should be thermally broken where possible.
    6)Seal and tape the joints of XT/TL-MF to ensure a continuous vapour control layer is created. Fill any gaps with foam filler.
    7)Plaster skim to finish.


    Specification Clause:
    The insulated drylining wall insulation shall be Xtratherm Thin-R XT/TL-MF manufactured to EN 13950 by Xtratherm, comprising a rigid Polyisocyanurate (PIR) core between composite foil facings.The XT/TL-MF_ _ _mm with Agrément certified Lambda value of 0.022 W/mK (PIR only), bonded to 12.5mm plasterboard, to achieve a U-Value of_ _ _ W/m2 K for the wall element. The insulated drylining plasterboard XT/TL-MF shall be mechanically fixed to battens, or proprietary system in accordance with instructions issued by Xtratherm. Refer to NBS clause K10 205, K10 15, K10 245


    Handling, Cutting and Storage:

    Xtratherm insulation should be stored off the ground, on a clean flat surface and must be stored under cover. The polythene wrapping is not considered adequate protection for outside exposure. Care should be taken to protect the insulation in storage and during the build process.
    The insulation boards can be readily cut using a sharp knife or fine toothed saw. Ensure tight fitting of the insulation boards to achieve continuity of insulation as asked for within the ACDs. Appropriate PPE should be worn when handling insulation. Please refer to Health & Safety data sheets on our website. The boards are wrapped in polythene packs and each pack is labelled with details of grade/type, size and number of pieces per pack.

    Durability:
    Xtratherm products are stable, rot proof and will remain effective for the life span of the building, dependent on specification and installation. Care should be taken to avoid contact with acids, petrol, alkalis and mineral oil, when contact is made, clean materials in a safe manner before installation.

    Write a review

    Note: HTML is not translated!
        Bad           Good

    Get best price of 102.5mm Xtratherm Thermal Line XT/TL (MF)?

    When you order from opencartworks.com, you will receive a confirmation email. Once your order is shipped, you will be emailed the tracking information for your order's shipment. You can choose your preferred shipping method on the Order Information page during the checkout process.

    The total time it takes to receive your order is shown below:

    The total delivery time is calculated from the time your order is placed until the time it is delivered to you. Total delivery time is broken down into processing time and shipping time.

    Processing time: The time it takes to prepare your item(s) to ship from our warehouse. This includes preparing your items, performing quality checks, and packing for shipment.

    Shipping time: The time for your item(s) to tarvel from our warehouse to your destination.

    Shipping from your local warehouse is significantly faster. Some charges may apply.

    In addition, the transit time depends on where you're located and where your package comes from. If you want to know more information, please contact the customer service. We will settle your problem as soon as possible. Enjoy shopping!

    All delivery charges are included in the final shopping basket and are dependent on the products Scottish Highlands & the Islands where additional shipping charges will apply.

    Please note that not all products will incur an additional delivery charge to the Scottish Highlands & the Islands – this is based on the costs from the manufacturer, distributor or courier providing shipping on our behalf. If your delivery address is in the Scottish Highlandsand Islands, a member of our helpline team will contact you prior to processing your ordershould an additional delivery charge apply.

    While we make every effort to ensure orders are delivered by the date required, we cannot guarantee availability from the manufacturer or the manufacturer's delivery schedules.

    Any variation to web delivery date given will be advised to you by email or telephone. If we are unable to make delivery because access is not possible, we reserve the right to make a failed delivery charge.

    pdf brochures
    Size Chart